Page 32 - Unistrut-Australia Catalog
P. 32

 30
www.unistrut.com.au
CONCRETE INSERTS
Standard Length: 3m or 6m
Mass: 2.80kg/m
Finish: Hot Dipped Galvanised.
Loading Data: The support capacity of any concrete insert depends largely on the strength of the concrete used. Therefore, Atkore and Unistrut® can not guarantee any particular load.
Recommended Pullout Loading*: Inserts 300mm and over 8.83kN per 300mm.
Factor of Safety; Approximately 3
Design load based on 34mpa concrete
NOTE: Exercise care during installation - Do not bend lugs. Lugs at 100mm centres
Standard Length: 3m or 6m
Mass: 1.94kg/m
Finish: Hot Dipped Galvanised.
Loading Data: The support capacity of any concrete insert depends largely on the strength of the concrete used. Therefore, Atkore and Unistrut® can not guarantee any particular load.
Recommended Pullout Loading*: Inserts 300mm and over 6.37kN per 300mm.
Factor of Safety: Approximately 3
Design load based on 34mpa concrete
NOTE: Exercise care during installation - Do not bend lugs. Lugs at 100mm centres
Standard Length: 300mm
Finish: Hot Dipped Galvanised.
Loading Data: Because the support capacity of any Concrete Insert depends largely on the strength of the concrete used, Atkore and Unistrut® can not guarantee any particular load.
Recommended Pullout Loading*: 22kN per 300mm. Recommended Loading*: The recommended design load is based on using two P1010 nuts at no less than 75mm O.C. and no closer than 50mm to either end of the insert. The distance between the insert centerline and the concrete edge must be a minimum of 75mm.
P1663 CI JOINT COVER
21 79
41
21 60
41
P1000CI
Mass: 4.5kg/100
Mass: 2.7kg/100
40
40
147
41
22
P3300CI
P3753 HEAVY DUTY INSERT
P4663 CI JOINT COVER
CONCRETE INSERTS STRUT SYSTEMS
P1000 Channel