Page 52 - Unistrut-Australia Catalog
P. 52

 50
www.unistrut.com.au
ENGINEERING DATA [BEARING AND DESIGN LOAD]
SAFE BEARING LOADS
Safety Factor: 2.5
Safety Factor: 2.5
Safety Factor: 2.5
Section
P1000 P2000 P3300 P4000
Section Listed
Section
P1000 P2000 P3300 P4000
End of Member
Section Listed
Section
P1000 P2000 P3300 P4000
Section Listed
Recommended Load kN
29.8 11.2 30.25 11.57
Load
Recommended Load kN
13.79 5.34 14.23 5.34
Load
Recommended Load Load kN
34.25 13.34 34.7 13.34
DESIGN LOAD DATA - TYPICAL STRUT CONNECTION
Safety Factor = 2.5 based on ultimate strength of connection. Load diagrams indicate up to two design loads, one for 2.5mm sections (listed as P1000), and one for 1.6mm sections (P2000). Loads are calculated using high tensile (Grade 8.8) screws.
NINETY DEGREE FITTINGS - (WHEN USED IN POSITION SHOWN)
P1026
P1346
P1458
P1000®: 6.67kN P2000: 3.34kN Both Ends Supported
P1068
P1325
P1326
P1000®: 2.22kN P2000: 2.22kN
P1000®: 8.9kN P2000: 6.67kN Both Ends Supported
P1000®: 2.22kN P2000: 2.22kN
P1026
P2484
P1346
P1000®: 4.45kN P2000: 2.22kN Both Ends Supported
P1000®: 13.34kN P2000: 6.67kN Both Ends Supported
P1000®: 5.34kN P2000: 4.45kN
ENGINEERING DATA STRUT SYSTEMS
FLAT PLATE FITTING - P1065
P1000®: 4.45kN P2000: 2.67kN Both Ends Supported
P1000®: 8.9kN P2000: 4.0kN
Both Ends Supported
P1000®: 6.67kN P2000: 4.45kN Both Ends Supported
Unistrut Concrete Insert